7. Identification - Plate data (Rif. 2)

A serial plate is affixed behind the unit, stating all characteristic data:
1) Manufacturer's name and address
2) Unit name and length
3) Unit code
4) Unit serial number
5) Voltage supply
6) Supply frequency
7) Current used when operating
8) Electrical power used when operating during refrigeration phase (fans+hot
cables+lighting)
9) Electrical power used when operating during defrost phase (armoured
resistances+hot cables+fans+lighting)
10) Lighting power (where applicable)
11) Net display surface
12) Type of refrigerant fluid with which the system functions
13) Mass of refrigerant gas with which each system has been loaded (only for units
with built-in motor)
14) Environmental climatic class and temperature of reference
15) Humidity protection class
16) Unit manufacturing order number
17) Unit production order number
18) Unit year of production
In the case of a request for technical assistance, please provide the following
information:
product name (Rif. 2 - 2); serial number (Rif. 2 - 4); work order number (Rif. 2 - 16).

8. Transport - specialised technician -

Loading/unloading operations must always be carried out by qualified personnel able
to check weights, exact lifting points, and the most appropriate means of transport,
both in terms of safety and capacity. The cabinets are supplied on a wooden platform
frame to the base for movement with forklift trucks. Use a manual or electrical forklift
truck that is suitable for moving the cabinet in question. It must have a nominal capacity
of at least 1,000 kg.
Always place the forks at the indicated points in order to avoid the risk of
overturning, and always completely insert the forks.
No unnecessary personnel should be present in the lifting area.
Balance the weight of the unit so as to ensure that the load remains in
equilibrium (Rif. 3)
DO NOT use transportation devices to lift:
with a capacity of less than 1,000 kg
with inappropriate characteristics or that have been affected by use
with non-standard or worn wires or cables
DO NOT use transportation procedures other than those indicated.

9. Storage

DO NOT store the units in uncovered areas where they are subject to weathering
and direct sunlight. Exposure to ultraviolet rays leads to permanent deformation of
the plastic materials and damages the unit's components.
The units must be stored in closed areas, at a temperature between -25°C and
+55°C and with relative humidity between 30% and 90%.
Before storing, check that the packaging is intact and that it doesn't show any
defects that could compromise the preservation of the units.
34
05060048 01 13/06/2012