Compliance with the requirements and standards are present in the generic facsimile of the
Declaration of Conformity at the end of this manual.
These models are excluded from the scope of the Directive 2014/68/EU in accordance with
article 4 paragraph 3 (and/or article 1 paragraph 2 letter f).
The performance of these refrigerated counters was determined through tests conducted in com-
pliance with the standard EN ISO 23953 in the environmental conditions that correspond to climat-
ic class 3 (25°C, 60% R.H.) see table:
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapour in dry air is one of the main points that affect the performance and
power consumption of the counters.
The safety test is carried out in accordance with standards IEC EN 60335-2-89 at an ambient tem-
perature of 32°C +/-2°C.
Declaration of
A copy of the conformity statement is annexed to the counter.
If the original copy of the Declaration of Conformity supplied with the unit is
conformity
lost, download a copy by filling out the form found in the footer of the home
page of the website www.arneg.it under "EU compliance".

9. Identification - Rating Plate

The cabinet features the serial number plate (Fig.2) with all the technical specifications:
1
manufacturer's name/logo
2
name and length of the cabinet
3
code of the cabinet
4
serial number of the cabinet
5
supply voltage
operating electrical power absorbed in the defrosting phase
6
(armoured heaters+hot wires+ fans+lighting)
7
usable display surface
8
type of refrigerant fluid used by the system to operate
9
environmental climatic class and temperature of reference
10
number of the job order based on which the cabinet has been manufactured
11
number of purchase order based on which the cabinet has been put in production
12
year of manufacture of the cabinet
13
EAC marking
14
operation class
weight of refrigerant gas loaded in every system
15
(only for cabinets with a built-in motor)
16
heating capacity
17
lighting power (where included)
18
class of protection against humidity
19
QR code
20
operating current consumption
05060194 01 05-2022
Temperature
dry bulb
Humidity
°C
20
16
22
25
30
27
40
35
23.9
Astana LX - Mini Astana LX
Relative
Dew
point
%
°C
50
9.3
80
12.6
65
15.2
60
16.7
55
20.0
70
21.1
40
23.9
75
30.0
55
14.3
Name
English
Weight of water va-
pour in dry air
g/kg
7.3
9.1
10.8
12.0
14.8
15.8
18.8
27.3
10.2
49