English
The EN 378 - EN 60079-10 standards guarantee that the R290 flammable refrigerant does not gener-
ate potentially explosive areas and that its use does not cause danger to persons and animals if the
instructions in this manual are respected.
i
Compliance with the requirements and standards are present in the generic facsimile of the
Declaration of Conformity at the end of this manual.
These models are excluded from the scope of the Directive 2014/68/EU in accordance with
article 4 paragraph 3 (and/or article 1 paragraph 2 letter f).
The performance of these cabinets was determined through tests conducted in compliance with
standard:
EN ISO 23953 in the environmental conditions that correspond to climatic class 3 (25°C, 60% R.H.) see table:
Environmental climatic classes as per UNI EN ISO 23953
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapour in dry air is one of the main points that affect the performance and
power consumption of the cabinets.
Declaration of
A copy of the conformity statement is annexed to the cabinet.
If you lose the original copy of the Declaration of Conformity supplied with the cabinet,
conformity
download a copy by filling out the form available on the internet addresses:
Italy: https://www.arneg.it/it/dichiarazione-di-conformita-del-prodotto
Abroad: https://www.arneg.it/en/declaration-products-conformity

10. Identification - Rating Plate

The cabinet features the serial number plate (Fig.2) with all the technical specifications:
1
manufacturer's name/logo
2
name and length of the cabinet
3
code of the cabinet
4
serial number of the cabinet
5
supply voltage
operating electrical power absorbed in the defrosting phase
6
(armoured heaters+hot wires+ fans+lighting)
7
usable display surface
8
type of refrigerant fluid used by the system to operate
9
environmental climatic class and temperature of reference
10
number of the job order based on which the cabinet has been manufactured
11
number of purchase order based on which the cabinet has been put in production
12
year of manufacture of the cabinet
13
EAC marking
14
operation class
weight of refrigerant gas loaded in every system
15
(only for cabinets with a built-in motor)
16
heating capacity
17
lighting power (where included)
32
Temperature
dry bulb
Humidity
°C
20
16
22
25
30
27
40
35
23.9
Relative
Dew
point
%
°C
50
9.3
80
12.6
65
15.2
60
16.7
55
20.0
70
21.1
40
23.9
75
30.0
55
14.3
Name
Weight of water va-
pour in dry air
g/kg
7.3
9.1
10.8
12.0
14.8
15.8
18.8
27.3
10.2