The performance of these refrigerated counters was determined through tests conducted in
compliance with the standard
correspond to climatic class 3 (25°C, 60% R.H.) see table:
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapour in dry air is one of the main points that affect the performance and
power consumption of the counters.
The safety test is carried out in accordance with standards IEC EN 60335-2-89 at an ambient
temperature of 32°C +/-2°C.
Declaration of
conformity

4. Identification - Rating Plate

The serial plate with all the technical specifications Fig. 2 is affixed to the side of the cabinet:
1
name and address of the manufacturer
2
name and length of the cabinet
3
code of the cabinet
4
serial number of the cabinet
5
supply voltage
6
power supply frequency
7
operating current consumption
8
operating electrical power absorbed in the refrigeration phase (fans+hot wires+lighting)
operating electrical power absorbed in the defrosting phase (armoured heaters+hot
9
wires+ fans+lighting)
10 lighting power (where included)
11 usable display surface
12 type of refrigerant fluid used by the system to operate
13 weight of refrigerant gas loaded in every system (only for cabinets with a built-in motor)
14 environmental climatic class and temperature of reference
15 class of protection against humidity
16 number of the job order based on which the cabinet has been manufactured
17 number of purchase order based on which the cabinet has been put in production
18 year of manufacture of the cabinet
19 heating capacity
20 QR code
i
For support, provide the manufacturer with:
- the product name (2); the serial number (4); the job order number (16).
- DO NOT remove the serial plate for any reason
05060070 03 05-2022
EN ISO 23953-2: 2016
Temperature
dry bulb
°C
20
16
22
25
30
27
40
35
23,9
A copy of the conformity statement is annexed to the counter.
If the original copy of the Declaration of Conformity supplied with the unit is
lost, download a copy by filling out the form found in the footer of the home
page of the website www.arneg.it under "EU compliance".
in the environmental conditions that
Relative
Dew
Humidity
point
%
50
80
12,6
65
15,2
60
16,7
55
20,0
70
21,1
40
23,9
75
30,0
55
14,3
Trade
Berlino 3
Weight of water
vapour in dry air
g/kg
°C
9,3
7,3
9,1
10,8
12,0
14,8
15,8
18,8
27,3
10,2