Maintenance And Cleaning; Dismantling The Cabinet - Arneg Berlino 3 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
MULTIPLEXING KIT
Ref.
Code
Q.ty
1
02047000
3
2
04230600
6
3
04480112
10
4
04711040
1
5
04711065
3
6
02940652
1

17.Maintenance and cleaning

ATTENTION!: BEFORE CARRYING OUT ANY MAINTENANCE WORK OR
CLEANING, FIRST DISCONNECT THE UNIT FROM THE VOLTAGE SUPPLY
BY MEANS OF THE GENERAL SWITCH. ALWAYS WEAR PROTECTIVE
GLOVES FOR CLEANING.
Food products can deteriorate due to microbes and bacteria.
Respecting hygiene norms is indispensable in order to guarantee protection of consumer health, as
well as respecting the chain of refrigeration, for which the sales point is the last controllable ring.
Cleaning of refrigeration units should be carried out as follows:
Cleaning of external parts (Daily / Weekly)
- On a weekly basis, clean the external parts of the unit, using neutral household detergents or soap
and water.
- Rinse with clean water and dry with a soft cloth.
- DO NOT use abrasive products or solvents that can affect the unit surface.
- DO NOT spray water or detergent directly on the electrical parts of the unit.
- DO NOT touch the unit with wet or damp hands or feet
- DO NOT use the unit if barefoot
- DO NOT use alcohol to clean the methacrylate parts (Plexiglas).
Cleaning of internal parts (Monthly)
Cleaning the unit's internal parts is done to destroy pathogenic micro-organisms so as to ensure
protection of merchandise.
Before beginning to clean the inside of the unit, it is necessary to:
- Completely remove all merchandise inside;
- Disconnect the unit's power supply using the main switch;
- Remove any removable parts, including display plates, grills, etc. These should be washed with
warm water and detergent that contains disinfectant, and then dried carefully;
- Carefully clean the tank, drip, and water discharge protection grill, eliminating all foreign bodies that
may have fallen into the suction grill, lifting the fan plate if necessary.
- If anomalous ice has formed, contact a Qualified Refrigeration Technician for assistance.
Complete the cleaning operation by reattaching the dry removable elements and by restoring the
electrical supply. Once internal operating temperature has been reached, the unit can be loaded with
the products to be displayed.
N.B.Avoid wetting fans, lights, electric cables, and all electrical devices in general during
cleaning operations.

18.Dismantling the cabinet

The unit must be disposed of in accordance with your country's waste management legislation and in
respect of our environment.
This product is considered by current legislation as hazardous waste. It must therefore be collected
separately and cannot be treated as household waste nor sent to a landfill. Before disposing of the unit,
the coolant must be collected and the lubricant oil removed. The user is responsible for delivering the
product for disposal to the collection centre specified by the local authorities or manufacturer for the
recovery and recycling of materials. This product consists of 75% recyclable materials. Materials used
in construction:
- Iron piping and sheet metal:
- Copper, Aluminium:
- Galvanized sheet metal:
- Foam polystyrene (R134a):
05060070 03 05-2022
Alignment pin profile D 10
Hexagonal nut M8
Ring D 8,5x24
Screw TCEI M8X35 (Cylindrical head and flush hexagon)
Screw TCEI M8X120 (Cylindrical head and flush hexagon)
Alignment pin D 4x80
lower frame, uprights, shelves
refrigeration circuit, electrical system and top strip
bottom panels, painted panels, base structure, shelves and trays
thermal insulation
Description
Berlino 3
English
35

Publicité

Table des Matières
loading