Start, Control, And Adjustment Of The Temperature - Arneg Bergen 2 Manuel D'installation Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 77
Bergen 2
English
Power
• the cabinet is designed for plug-in connection (not supplied).
• attach a plug suited to the electrical connection, on the power cable, in
power supply
• the supply lines of the electric energy should meet the requirements of power
• check that the power line:
Automatic
safety switches
• protect the upstream cabinets with omnipolar circuit breakers with suitable
• inform the operator of the position of the switches so that they can be reached
Before
connecting
• consult the wiring diagrams annexed to the cabinet
• make sure that the rating plate data matches the characteristics of the electri-
• check that power supply voltage is the one reported on the rating plate.
• remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
• proceed with wiring
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protection devices; modify the system to differentiate the enabling of
the various devices.

15. Start, control, and adjustment of the temperature

Checking of the refrigeration temperature is carried out with the electronic controller (Fig. 10) are
active.
Procedure:
Step
1
disconnect the power supply from the main switch 1 (Fig.11)
2
insert the plug (Fig.11) 2 and restore the power supply.
3
operate the electrical panel switch (Fig.10)
Result: The cooling system starts functioning immediately.
36
compliance with safety regulations: yellow-green=earth; light blue=neutral;
brown=phase.
consumption of the cabinet (chap.10).
- has the appropriately sectioned cables to ensure compliance with the maxi-
mum expected voltage drop of 5%
- is protected against overcurrents and earth leakage in compliance with the
current regulations
- for the power supply lines measuring more than 4-5 m, increase the section
of the cables appropriately.
i
The replacement of the damaged power cord is reserved to the manu-
facturer or a body authorized by the same.
DANGER! Live parts. Short circuit. Electrocution
The automatic circuit breaker must be such that they do not open the
circuit on the neutral, without simultaneously opening on the phases
and, in any case, must allow complete disconnection in conditions of
category III overvoltage
characteristics that will also function as master switches to section off the line.
immediately in the event of an EMERGENCY.
DANGER! Live parts. Short circuit. Electrocution
DO NOT connect more than one appliance to the same power socket.
DO NOT use adapter plugs
cal system to which the cabinet must be attached
The power cable must be laid so that it does not harm or risk harming
persons.
Action
05060176 00 11-09-2018

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bergen 2 bt/tn gi r290

Table des Matières