Automati c
safety switches
• protect the upstream cabinets with omnipolar circuit breakers with suitable
• inform the operator of the positi on of the switches so that they can be reached
MINI ASTANA LX
with built-in
condensing unit
Mini Astana LX with built-in unit, features an electrical power supply kit con-
sisti ng of a switchboard with circuit breaker and cable (5 m) with IEC309 3PNT
32A plug, shown in Fig.21, and two power supplies:
Before
connecti ng
• consult the wiring diagrams annexed to the counter
• ensure that the rati ng plate data matches the characteristi cs of the electrical
• check that power supply voltage is the one reported on the rati ng plate
• remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
• proceed with the connecti on.
i
If the electrical supply is interrupted, the electrical equipment of the shop will not restart,
triggering the overload protecti on devices; modify the system to diff erenti ate the start-up of
the various devices.
17. Checking and adjusti ng the temperature
The refrigerati ng temperature is checked via the electronic controller (Fig.19)
i
To change the controller programming, call the manufacturer.

18. Cabinet loading

ATTENTION! Opening the doors. Tilti ng of the cabinet. Injuries, wounds.
DO NOT open all the doors at the same ti me Fig.28
Before loading goods, wash and disinfect the cabinet as indicated in chapter 22.
05060194 01 05-2022
DANGER! Live parts. Short circuit. Electrocuti on
The automati c circuit breaker must be such that they do not open the
circuit on the neutral, without simultaneously opening on the phases
and, in any case, must allow complete disconnecti on in conditi ons of
category III overvoltage.
characteristi cs that will also functi on as master switches to secti on off the line
immediately in the event of an EMERGENCY.
DANGER! Live parts. Short circuit. Electrocuti on
Do not use sockets already connected to other users, nor reducers,
multi ple sockets or plugs.
provide a suitable socket (Fig.22) which must meet standards IEC 309
and must be compati ble with the electrical characteristi cs of the plug
supplied with the cabinet (Fig.21).
The electrical cable must be stretched to avoid damaging it or endanger-
ing people.
DANGER! Live parts. Short circuit. Electrocuti on
Check that the att achments of the lighti ng systems (fl oors, roof, ceil-
ing) are properly inserted and locked into their housings to avoid
disconnecti ons during cleaning and maintenance operati ons, that may
cause harmful electric shocks.