Electrical Connection - Specialised Technician - Arneg Sendai Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Sendai-SendaiR290
English
For inclined multiplexing, proceed as follows:
1
Adjust the height of the front of the rear cabinet using the four removable supports
so as to copy the height of the rear side of the front cabinet as far as possible.
2 - Select the inclination of the rear cabinet, copying that used on the front cabinet.
3 - Compensate for the difference in height (Part.B) between the two cabinets by
adjusting the feet on both. It is preferable to raise all four feet on one unit above
25mm rather than lowering four on the other.
Do not incline the cabinet by adjusting just one foot (Rif. 24).
To avoid completely removing the removable supports during adjustment
choose an appropriate height for the front cabinet.
If it is not possible to perfectly align the connection, return to point 1 and choose a
different height for the rear cabinet (just a height higher or lower than the current
one).
For fixing and connections refer to the instructions for front/rear multiplexing.

14.Electrical connection - specialised technician -

BEFORE STARTING ANY OPERATION, FIRST DISCONNECT THE SYSTEM FROM
THE POWER SUPPLY!
The systems must be completed in accordance with the regulations that
govern construction, installation, use, and maintenance as envisaged under
the norms in effect in the country where the unit is installed.
ARNEG Spa declines any responsibility with regards to the user and third-
parties for damages caused by breakdowns or malfunctioning of the systems
installed upstream to the unit and for damages caused by the same due to
causes directly attributable to malfunctioning of the electrical system.
The unit must be protected upstream by an automatic omnipolar
thermomagnetic switch with appropriate characteristics. This must also act as
a general line disconnection switch.
The unit comes with a connection ready for a plug (NOT SUPPLIED). Attach a
plug of suitable capacity for the electrical connection, onto the power lead in
compliance with safety rules: yellow-green = earth sky blue = neutral brown
=live and conform to the national regulations in effect
Establishment of the electrical power supply line to the point of where it connects to the
unit is the responsibility of the Client. The dimensions of the electrical energy power
supply line must be determined in accordance with the electrical power used by the
unit (see Technical Specifications).
Remove any metal objects worn: rings, watches, bracelets, earrings, etc.
Check the electrical diagrams before carrying out the connection
Check that the voltage supply is as specified on the plate data.
For power lines exceeding 4-5 metres in length, increase the cable section
accordingly.
Tell the operator where the switch is so that it can be reached quickly in an
EMERGENCY.
To guarantee correct operation, the maximum voltage variation must be between +/
- 6% of the nominal value.
Check that the power line has appropriate section cables, is protected against
overcurrent and dispersions towards earth, in compliance with current standards.
In the event of an interruption to the electricity supply, check that all store electrical
appliances can reboot without causing the overload protections to intervene. If not,
alter the system in order to differentiate between the start-up of the various
devices.
40
The electrical system must be earthed!