required by the following European Directives:
Directive
Machinery Directive - 2006/
42/CE
2004/108/CE Electromagnetic
Compatibility
2006/95/CE Low Voltage
RoHs Directive 2011/65/CE;
(restricted use of certain
hazardous substances in
electrical and electronic
equipment)
European Regulation
EC-1935/2004
(on materials intended for
contact with the goods)
Refrigeration systems and
heat pumps - Safety and
environmental requisites
Electrical installations for
explosive atmospheres
The standards EN 378:2008 - EN 60079-10 guarantee that the flammable coolant R290 does
not generate potentially explosive areas and its use does not generate hazards for people and
animals ifthe istructions given in this manual are observed.
i
Article 3 section 3 of Directive CEE 97/23 (PED) does not apply to these cabinets.
The performance of these refrigerated cabinets was determined through tests conducted in
compliance with standard:
EN ISO 23953:2012 in environmental conditions corresponding to climatic class 3
(25 °C , 60% U.R.) see table:
Environmental climatic classes as per UNI EN ISO 23953
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapor in dry air is one of the main points that affect the performance and
power consumption of the cabinets
Declaration of
A copy of the conformity statement is annexed to the cabinet
conformity
If you lose the original copy of the Declaration of Conformity supplied with
the cabinet, download a copy by filling out the form available on the internet
addresses:
- for Italy: http://www.arneg.it/conformita/it
- overseas: http://www.arneg.it/conformita/en
05060048 01 13/06/2012
EN ISO 14121:2007; EN ISO 12100-1:2005; EN ISO 12100-2:2003; EN
378-2:2009; EN 378-3:2008; EN 378-4:2008; EN 60079-10-1:2010
EN 61000-3-2:2006; EN 61000-3-12:2005; EN 55014-1:2006; EN
55014-2:1997;
EN 60335-1:2008; EN 60335-2-89 :2002/A2:2007
EN 50581:2012
EN 1672-2
EN 378:2008
EN 60079-10
Dry bulb temp.
Relative Humidity
°C
20
16
22
25
30
27
40
35
23,9
Sendai-SendaiR290
Harmonised standards applied:
Dew point
%
50
80
65
60
55
70
40
75
55
Weight of
water vapour in
dry air
g/kg
°C
9,3
7,3
12,6
9,1
15,2
10,8
16,7
12,0
20,0
14,8
21,1
15,8
23,9
18,8
30,0
27,3
14,3
10,2