1. Introduction

NOTE!
These instructions must be followed to ensure
safe and proper installation, operation and
maintenance of the motor. They should be brought
to the attention of anyone who installs, operates
or maintains the motor or associated equipment.
The motor is intended for installation and use by
qualified personnel, familiar with health and safety
requirements and national legislation. Ignoring these
instructions may invalidate all applicable warranties.

1.1 Declaration of Conformity

The conformity of the end product according to Directive
2006/42/EC (Machinery) has to be established by the
commissioning party when the motor is fitted to the
machinery.

1.2 Validity

These instructions are valid for the following ABB electrical
machine types, in both motor and generator operation:
series MT*, MXMA,
series M1A*, M2A*/M3A*, M2B*/M3B*, M4B*, M2C*/M3C*,
M2F*/M3F*, M2L*/M3L*, M2M*/M3M*, M2Q*, M2R*/M3R*,
M2V*/M3V*
in frame sizes 56 - 450.
There is a separate manual for e.g. Ex motors 'Low voltage
motors for explosive atmospheres: Installation, operation
and maintenance and safety manual (3GZF500730-47)
Additional information is required for some machine types
due to special application and/or design considerations.
Additional manual is available for the following motors:
– roller table motors
– water cooled motors
– smoke extraction motors
– brake motors
– motors for high ambient temperatures
– motors in marine applications for mounting on open deck
of ships or offshore units
Standard_Manual_LV_Motors_ML_revF_Book.indb 5

2. Safety considerations

The motor is intended for installation and use by qualified
personnel, familiar with health and safety requirements and
national legislation.
Safety equipment necessary for the prevention of accidents
at the installation and operating site must be provided in
accordance with local regulations.
WARNING!
Emergency stop controls must be equipped with
restart lockouts. After emergency stop a new start
command can take effect only after the restart
lockout has been intentionally reset.
Points to be observed:
1. Do not step on the motor.
2. The temperature of the outer casing of the motor
may be hot to the touch during normal operation and
especially after shut-down.
3. Some special motor applications may require additional
instructions (e.g. when supplied by frequency
converter).
4. Observe rotating parts of the motor.
5. Do not open terminal boxes while energized.
Low voltage motors manual, 3GZF500730-85 Rev F 02-2015 | ABB Motors and Generators 5