OIL LIGHT (P)
Glows if oil pressure drops too low.
PTO SWITCH (O)
The PTO switch is pulled out approximately 1/4" to
engage the PTO. To disengage, push in. Do not
use excessive force. To overcome the detent
requires approximately 5 lb force to pull and
engage the PTO switch.
ALTERNATOR LIGHT (R)
Glows if electrical system is not charging.
Blade-type fuse (20 amp) protects the electrical
circuit.
Relays (V)
Relays are located on the front of the engine
compartment. See parts manual electrical diagram
for function.
RANSOMES 700 Series EC Tractors
SAFETY AND OPERATORS MANUAL
HORN BUTTON (Optional) (S)
Push to activate. Sounds automatically if engine is
overheating or if parking brake is on when forward/
reverse pedal is engaged
FUEL GAUGE (T)
Displays fuel level in tank.
TEMPERATURE GAUGE (U)
Displays temperature of engine coolant.
IGNITION SWITCH (K)
Insert the ignition key into the switch and turn
clockwise to start the engine. Return to fully left
position to stop the engine. Turning the key
clockwise operates the cylinder glow plug to pre-
heat the chamber prior to starting.
NOTE: The keyswitch has two resistance settings
when turned to the right. Turning the key
clockwise to the first setting operates the cylinder
glow plug to pre-heat the chamber prior to starting.
Turning the key further clockwise, with the
increased resistance, engages the starter.
FUSE (W)