The flame is unstable and reddish,
sometimes the alarm buzzes:
Burner block
The oven fails to reach the Set Point
but always goes over 20°
Gas valve output pressure
unregulated
Side panels excessively low
Reset for the wrong gas type
Wrong gas supply pressure
UK/27
Check that the output pressure from
the valve is 0 otherwise adjust; if it
fails to adjust, replace the valve
Lift the side panels
Check that the oven is regulated
properly for the type of gas power
supply and the outgoing pressure
from the valve gas is 0 mbar.
Ensure that gas and supply pressure
are set as shown in TAB. 1 of the
instruction manual (for your country)