Nordcap MORETTI T75G Mode D'emploi page 221

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TAB.1
T64G
Nominal Gas Consumption @ Max Rate (MJ/h)
Nominal Gas Consumption @ Economy/Ignition Rate (MJ/h)
Gas Inlect Connection (Fig. 10 item W).
Stru
Percentage fan revs on start-up
Strr
Upward ramp percentage fan revs
Min
Percentage fan revs at minimum
MAX
Percentage fan revs at maximum
ECO
Percentage fan revs on stand-by
Brnd
Burner start-up delay (in seconds)
brnS
Burner start-up duration (in seconds)
brnr
Upward ramp duration (in seconds)
Venturi cone
regulator screw
minimum supply pressure in kPa
Pressure regulator (Fig. 28 item Z) screw
adjustment in kPa
Injectors diameters in mm (nozzle)
T75G
Nominal Gas Consumption @ Max Rate (MJ/h)
Nominal Gas Consumption @ Economy / Ignition Rate (MJ/h)
Gas Inlect Connection (Fig. 10 item W).
% Gas startup
% Gas rising ramp
% Gas min
% Gas max (% Fan revs at maximum)
% Gas eco stand-by
Rit. Acc. Bruciatore
Dur. Acc. Bruciatore
Venturi cone
regulator screw
minimum supply pressure in kPa
Pressure regulator (Fig. 28 item Z) screw
adjustment in kPa
Injectors diameters in mm (nozzle)
WARNING ! In case you have to modify the appliance from feeding with Natural gas to Universal
LPG Gas or viceversa, at the end of the operations replace the plates with the ones related to the
feeding gas type in which the appliance has been converted.
AU (Australia)
Fig. 22 X=mm
AU (Australia)
(% Fan revs at Economy)
Fig. 22 X=mm
AGA CERTIFICATION NUMBER: 7282
43
Natural gas
13,9
Natural gas
CONESNAPED MALE GAS MANIFOLD G 1/2"
Natural gas
34
44
20
60
20
20
15
1500
14,5 mm
1,13
0,0
Nil
AGA CERTIFICATION NUMBER: 7282
CONESNAPED MALE GAS MANIFOLD G 1/2"
Natural gas
25
47
25
60
25
20
15
12
1,13
0,0
Nil
/ 37
Universal LPG gas
/ 12,7
Universal LPG gas
Universal LPG Gas
32
42
20
54
20
24
15
1500
14,5 mm
2,75
0,0
4,4 mm (brass)
Nozzle (Fig. 26 item S) between gas
valve and venturi cone
18 mm (stainless steel
Nozzle (Fig. 25 item R) between burner
head and fan
67
27
Universal LPG Gas
34
48
34
90
34
20
15
6
2,75
0,0
4,4 mm (brass)
Nozzle (Fig. 26 item S) between gas
valve and venturi cone
14 mm (stainless steel
Nozzle (Fig. 25 item R) between burner
head and fan
)
)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

493100075000

Table des Matières