Inspect the fishplates, load bolts and screw connections for
damage.
Connecting cable
Check that the length is adequate.
Check whether the cable diameter is sufficient for the
planned length (see Table 5 and 6 on page 12).
Check the entire length of the cable for visible damage.
Control cable
Check that the length is adequate.
Check the entire length of the cable for visible damage.
9.3

Assembly

Requirements
Assembly may only be performed by trained personnel.
The workplace must have adequate lighting.
Anchor hoist
DANGER!
Incorrect anchoring!
Danger of death from falling! Risk of being injured by falling
objects!
Only attach the hoist at the specified anchorage bore-
holes with the specified anchoring devices.
The wire rope must run into the hoist vertically (see
Fig. 2).
If greater payload is required: See the specifications in
' 4.9 Load limits' on page 10.
Danger of severe injuries caused by incorrect anchoring!
High-strength, galvanized bolts and screws can become brittle
and break. Risk of falling and of being injured by falling ob-
jects!
High-strength galvanized bolts / screws (10.9 or 12.9)
may not be utilized for anchoring.
Utilize bolts / screws with the specified strength.
Cotter pins inserted incorrectly!
Risk of being injured by falling objects!
Insert the cotter pin according to Fig. 21.
ATTENTION!
Incorrect installation position!
Damage to the equipment may occur!
The equipment will be damaged if incorrect or insufficient
lubricant is used!
The hoist must not be mounted horizontally on the flat
side.
Attach the hoist in such a way that the flat side only
points to the side or upward, see Fig. 2.
EN-12
Use screws with self-locking nuts to stop them from being
lost.
Secure the bolts with a cotter pin or similar lock.
See Fig. 2 and Table 4 on page X.
ATTENTION!
Incorrect anchoring!
Can result in damage to the device!
The unit can be damaged if fastened to the wrong anchor-
age boreholes!
Only attach the hoist at the specified anchorage bore-
holes with the specified anchoring devices.
Securing to anchorage boreholes that are positioned
diagonally opposite one another is prohibited.
Securing to the A3 + A4 anchorage boreholes in ac-
cordance with Fig. 2 is prohibited.
Securing to anchorage points A:
Secure the hoist to at least two anchorage points using
screws or bolts.
A1 + A2 or A2 + A3 or A1 + A4.
Securing to anchorage points B:
Secure the hoist with screws or bolts.
Electrical connection
DANGER!
Danger of electric shock! Danger of severe accidents!
All of the work undertaken and the electrical connections must
concur with the national regulations applicable in the respec-
tive country.
Only electricians are permitted to make the electrical
connections.
Danger through unauthorized use!
The electrical connection on the operator's side must be
connected in such a way that the hoist can be secured against
unauthorized use! Suitable protective measures include:
Lockable Emergency Off device
Lockable main switch
Key-switch
Removable operating controls
Danger of severe accidents! Danger of electric shock!
The electrical connections must be made in accordance with
the details given in this manual in order to prevent electrical
hazards.
The electric connection must be established in accordance with
EN 60204-32.
The equipment must be earthed via the power supply cable. The
earthing function must be tested (isolation and protective conduc-
tor inspection). Additional measures may be necessary.
A generator rated at 3 times the hoist's nominal power can be
used if necessary (generator's nominal power rating [kVA] =