Reading The Running Hours Counter; Care And Maintenance - Tractel tirak L 500 P Série Manuel D'installation Et De Manutention Original

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Annual safety inspection
The safety inspection must be carried out annually.
The safety inspection may only be undertaken by authorized
maintenance personnel, see ' 15.1 Authorized maintenance per-
sonnel' on page 20. Depending on the usage conditions (e.g.
operation in an extremely dirty environment), an intermediate
inspection may be necessary.
When using rotation-resistant wire ropes:
Depending on the application and the environmental conditions
(suspended load, dirt on the wire rope, etc.) the hoist's traction
sheave may become prematurely worn, The traction sheave
must be changed if it is found to be worn.
We recommend that the system is tested in our factory by
TRACTEL Greifzug GmbH.
General overhaul
The general overhaul periods are, at the latest (depending upon
which occurs first):
250 operating hours for devices with a rope speed of 12
m/min or more,
500 running hours for devices with a rope speed of 9 m/min
or less
10 years after manufacture
If a general overhaul has been carried out then the period com-
mences anew.
A general overhaul of the hoist must only to be undertaken by
TRACTEL Greifzug GmbH or a hoisting gear workshop that has
been approved by TRACTEL Greifzug GmbH.
Contact TRACTEL Greifzug GmbH or your supplier with regards
to this test.
Exceptional tests
After an emergency descent, the hoist must always be tested in
manual mode by TRACTEL Greifzug GmbH or a hoisting gear
workshop that has been authorized by TRACTEL Greifzug
GmbH (see ' 10.4 Emergency descent' on page 17).
Any damaged or worn part found must always be replaced.

15.3 Reading the running hours counter

The running hours counter is located in the hoist's terminal box.
The running hours counter counts the time in which the hoist is in
operation as running hours (UPWARD or DOWNWARD move-
ments).
DANGER!
Danger of death due to electric shock!
Disconnect the hoist from the power supply by pulling out
the plug.
G1035.2 - 11/2014
Pull out the power plug.
Open the terminal box.
Read the running hours counter:
Note the running hours in the logbook.
Close the terminal box.

15.4 Care and maintenance

Please observe the measures in chapter 12 and 13 of these
instructions.
Interval
Work
Daily
Check the anchorage of the
hoist
Inspect the wire rope for
clinging dirt
Functional tests (see chapter
' 9.4 Commissioning' on
page 14)
Weekly
Check the wire rope, see
page 22
Check the connecting cable
and control cable
Every 50
Traction sheave external
running
teeth (only model series X
hours
2050), see page 23
1 x annually –
Hoist safety inspection
250
/ 500
General overhaul of the hoist TRACTEL Greifzug
1)
2)
Running
hours / after
10 years
3)
Whenever
See page 22:
necessary
Clean the wire rope
Lubricate the wire rope
Replace the wire rope
Clean the rope reel and rope
guide
Clean the limit switch and
the activator
Lubricate the limit switch
activator
Grease the axle for the hand
crank
Replace the cable
Devices with 50 Hz and with rope speed of 12 m/min or more
1)
Devices with 50 Hz and with rope speed of 9 m/min or less
2)
Depending upon which occurs first
3)
Operation and Installation Manual
Implementation
Operating
personnel
Operating
personnel
Operating
personnel
Authorized mainte-
nance personnel
GmbH or a hoisting
gear workshop that
has been approved
by TRACTEL
Greifzug GmbH
Trained person
nominated by the
operator
Electrician
EN-21

Publicité

Table des Matières
loading

Table des Matières