PARAMETER
DEFINITION
22
Master/Slave closing off set [s]
23
ESPE OPEN input polarity
24
ESPE CLOSE input polarity
25
KEY input polarity
26
START 1 input polarity
27
START 2 input polarity
28
AUX IN1 input polarity
29
AUX IN2 input polarity
30
AUX OUT input polarity
31
Leaf Weight setting
Force level during Reset and
32
LP procedure
Opening Angle reduction
33
percentage level [%]
Closing mode in non-Manual
34
mode
Disabled people opening
35
speed
36
Battery operation
37
START 2 input confi guration
Type of switch logic selector
in use
38
For detailed information about
the connection please refer to
the specifi c documents
39
Full closing speed [°/s]
Partial opening percentage
40
level [%]
Anti-crushing during closing
41
with spring
Default setting for all
SD
parameters and point reset
LP
Leaf parameter acquisition
In
System information
INSTALLATION MANUAL
MIN MAX DEFAULT
PERSONAL
0
100
0
 
0
1
1
 
0
1
1
 
0
1
1
 
0
1
0
 
0
1
0
 
0
1
0
 
0
1
0
 
0
1
0
 
0
3
0
 
0
9
5
 
0
50
0
 
0
1
0
 
0
1
0
0
2
0
1
2
0
1
3
0
5
15
8
50
90
70
0
1
0
 
 
 
/
 
 
 
/
DESCRIPTION
Master motor delay time during closing with respect to the slave motor. 100ms step
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = N.O. Normally open
1 = N.C. Normally closed
0 = Automatic (detected during LP)
1 = Weight Level Low
2 = Weight Level Medium
3 = Weight Level High
It regulates the motor force when the door is operated after a reset
(0 = minimum force, 9 = maximum force)
The opening angle, during normal operation, shall be reduced compared with the one detected
during the stop acquisition procedure, to allow operation in the absence of the mechanical stop
(adjustment step 1%)
0 = Motor close-back
1 = Spring close-back
0 = Low Energy
1 = speed as per parameters 1 and 2
0 = standard operation
1= continuous operation
2 = panic operation
0 = Operation as described at paragraph 21
1 = Disabled People opening : enabled in manual logic
2 = Disabled People opening: enabled in all logics
0 = Selector in header, normal logics
1 = 3-position rotary selector
2 = 4-position rotary selector
3 = Selector in header,Manual-Auto logics
5°/s ÷ 15°/s (adjustment step 1°/s)
50% ÷ 90% (adjustment step 2%)
0 = Motion Stop
1 = Motor re-opening
It restores all the parameters to the default values and resets the acquired path.
Procedure:
1- Select the command using the [+] and [-] buttons;
2- Press [ENT];
3- When [--] is displayed, press [ENT] again for 5 seconds to validate the operation;
4- When [--] disappears, release the [ENT] button
Path acquisition.
Procedure:
1- Select the command using the [+] and [-] buttons;
2- Press [ENT];
3- When [--] is displayed, press [ENT] again for 5 seconds to validate the operation;
4- When [--] disappears, release the [ENT] button.
Procedure:
1 - Select the command using the [+] and [-] buttons;
2 - Press [ENT];
3 - Select the parameter to be displayed using the [+] and [-] buttons;
4 - Press [ENT];
5 - Press [ESC] to return to the selection of the paramters to be used.
VISTA SW 260 SXL / VISTA SW 260 MXL -
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vista sw 260 mxl

Table des Matières