DEFINITION
PARAMETER
Mode
13
Single/Dual
Electric lock activation
14
according to the selected logic
AUX-IN 1 auxiliary input
15
confi guration
AUX-IN 2 auxiliary input
16
confi guration
AUX-OUT auxiliary output
17
confi guration
18
Safety sensor confi guration
19
Multi Master address
20
Opening safety by-pass [%]
21
Master/Slave opening off set [s]
28 -
VISTA SW 260 SXL / VISTA SW 260 MXL
INSTALLATION MANUAL
MIN MAX DEFAULT
PERSONAL
0
2
0
 
0
3
3
 
0
16
0
 
0
16
1
 
0
5
0
 
0
3
0
 
0
15
0
 
0
40
0
 
0
100
0
 
DESCRIPTION
0 = Single
1 = Dual Master
2 = Dual Slave
0 = never
1 = One EXT Radar
2 = Two Radars, One INT Radar
3 = Always (1 INT Radar, 1 EXT Radar, 2 Radars)
0= Disabled People opening
1= Emergency opening
2 = Door interlock with priority
3 = Door interlock without priority
4 = Lock Release feedback
5 = Lock Release command
6 = Single Command with Master/Slave operating mode
7 = Stand by mode activation
8 = It resets the door after the Stand by
9 = Step-by-Step (1 pulse opens, 1 pulse closes)
10 = Fire Emergency opening
11 = Manual logic setting
12 = Closed Stop logic setting
13 = Disabled People opening in manual mode
14 = Step-by-Step with automatic closing-back (pause time expressed in minutes rather than in
seconds
15 = Closed door contact
16 = Full or Partial Open selection
0= Disabled People opening
1= Emergency opening
2 = Door interlock with priority
3 = Door interlock without priority
4 = Lock Release feedback
5 = Lock Release command
6 = Single Command with Master/Slave operating mode
7 = Stand by mode activation
8 = It resets the door after the Stand by
9 = Step-by-Step (1 pulse opens, 1 pulse closes)
10 = Fire Emergency opening
11 = Manual logic setting
12 = Closed Stop logic setting
13 = Disabled People opening in manual mode
14 = Step-by-Step with automatic closing-back (pause time expressed in minutes rather than in
seconds
15 = Closed door contact
16 = Full or Partial Open selection
0 = Interlock
1 = Door open state
2 = Door closed state
3 = Fault
4 = Lock command repetition
5 = Door in motion
0 = Monitoring disabled
1 = Monitoring enabled for closing sensor
2 = Monitoring enabled for opening sensor
3 = Monitoring enabled for opening and closing sensor
0= No Multi-Master management
0 ÷ 15= Univocal address for Multi-Master connections
Opening safety by-pass angle, percentage of the total stroke.
Slave motor delay time during opening with respect to the master motor. 100ms step

Publicité