Electrical Connection (Pag. 7 - Pag. 9) - Specialized Technician - Arneg Panama 2 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Panama 2
English
Join the risers and the brackets, using the screws supplied
Reassemble the backrests and any other covering elements possibly supplied.
Make sure the alignment pins are inserted in their provided seats.
Channel combination Kit
Pos.
Denomination
1
Hand rail alignment pin
2
Hand rail alignment pin
3
Screw TCEI M8x80
4
Screw TCEI M8x120
5
Screw TCEI M6x25
6
Nut M8
7
Nut M6
8
Washer

12.Electrical connection (Pag. 7 - Pag. 9) - specialized technician -

BEFORE ANY OPERATION REMOVE VOLTAGE TO THE SYSTEM!
system must have a grounding connection!
The systems must be set up in accordance to the norms that regulate their
manufacture, installation, use, and maintenance foreseen by the norms in force
in the country where the cabinet is installed.
ARNEG Spa rejects any responsibility toward the user and third parties for
damages caused by breakdowns or malfunctions of the systems arranged
upstream of the cabinet and for damages to the cabinet that directly stem from
causes ascribable to an electrical system malfunction.
The cabinet must be protected upstream with an automatic, omnipolar
magneto-thermal switch having adequate characteristics and which will serve
as a main line disconnecting switch.
It is the Client's responsibility to arrange the electrical power supply line up to the point
of connection to the cabinet. Sizing of the electrical power supply line must be
performed in accordance to the power absorbed by the cabinet.
Remove all metallic objects worn: rings, watches, bracelets, earrings, etc.
Consult the wiring diagrams before performing the connection.
Check that the power supply voltage is the one reported on the rating plate.
Instruct the operator on the position of the switch so that it may be timely reached in
case of an EMERGENCY.
To ensure normal operation, the maximum variation of the voltage must range
between +/- 6% of the nominal value.
Check that the power supply line has wires with an appropriate diameter, that it is
protected against overcurrents, and that the leakages to ground are in compliance to
the norms in force.
If the electrical power supply is interrupted, check that all the electrical devices of the
store can restart without triggering the intervention of the overload protections; if
otherwise, modify the system so as to differentiate activation of the various devices.
The installer must provide the anchoring devices for all the wires in input and outpout
to/from the cabinet.
Check that the connections of the various lighting devices (floors, roof,
superstructure) are properly inserted and locked into their respective sockets,
so as to prevent disconnections during cleaning and maintenance operations
that may cause electrical shocks harmful to the operator.
32
Code
Pcs.
02940652
3
02047000
3
04711030
1
04711065
5
04711098
1
04230600
8
04230000
1
04480112
6
The electrical
05060117 00 06/05/2011