Télécharger Imprimer la page

Fimar CAM300 Emploi Et Entretien page 40

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 44
OIL CHANGE
BEFORE CARRYING OUT THE OIL CHANGE, TAKE THE MACHINE TO A SUITABLE PLACE FOR THIS KIND OF
OPERATION AND DISCONNECT THE CURRENT OUTLET FROM THE POWER SUPPLY PANEL.
1. Remove the safety casing (1, fig. 13) by unscrewing the 4 (6) fixing screws to enter the machine.
2. Remove the casing as shown in fig. 14.
3. Position a container under the oil discharge opening.
4. Loosen and totally remove the cap positioned near the level sight glass (a).
5. For a fast oil discharge, loosen and remove the cap (b).
6. Once the tank has been completely discharged, fit the cap (a) again and tighten it well.
7. Fill the tank by the opening provided (b) with oil as indicated by the manufacturing company.
8. Once the maximum level shown by the sight glass is reached (about ¾) tighten the filling opening and
close the casing by means of the screws.
OIL DISPOSAL IS TO BE CARRIED OUT IN COMPLIANCE WITH THE STANDARDS IN FORCE.
1
Fig. 14
Recommended oil types:
-
TERESSO 100
-
MOBIL RADIUS 425
-
SCHELL CORENA 100
-
BP ENERGOL RC 100
-
IP SIANTIAX
-
VANGUARD PRESSURE RA 77
b
a
Fig. 13
Fig. 2
!

Publicité

loading