Troubleshooting
Fault
The vacuum suddenly stops
Dust leaks from the vacuum
Electrostatic current on the
vacuum
Causes
Clogged primary filter
Clogged suction pipe
Insufficient air
The filter is torn
Inadequate filter
Non existent or inefficient
earthing
-58-
Tutti i diritti riservati / All rights reserved
Tous droits réservés / Alle Rechte vorbehalten
Remedies
Shake the filter. Replace it if
this is not sufficient
Check the suction pipe and
clean it
Increase the inlet air pressure
Make sure that the pressure
in the air main is adequate
Change it for another of iden-
tical category
Change it for another of suit-
able category and check
Make sure that the machine
has been correctly grounded
It is essential for the suction
pipe to be of the antistatic
type