n_limit pos eff
From setpoint limiting
r1084
[3050.8]
n_limit neg eff
<5> [3095.7]
r1087
n_act smooth
r0063
n_act smooth signal
0...1 000 000 ms
[4710.7]
<5>
p2153 (0)
r2169
[8011.1]
[8012.5]
n_act unsmoothed
[8013.1]
r0063[0]
[4715.7]
<4>
Smoothing
<1> VECTOR: Calculated.
<2> VECTOR:
Depending on the drive unit (250 or 400 μs).
<3> VECTOR:
Depending on the drive unit (1000 or 1600 μs).
<4> Only for VECTOR.
<5> Only for SINAMICS S120 and SERVO.
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Speed signals 1
p0115[1] (125.00 μs)
p0115[1] (<2>)
0
ZSW Monitor 1
n
r2197
r2197.6
[2534.3]
n
|n_act| > n_max
F07901
"motor overspeed"
0.00...60 000.00 RPM
p2162[D] (0.00)
n_thresh val 1
0.00...210 000.00 RPM
p2141[D] (5.00)
1
1
0
0
0.00...210 000.00 RPM
p2155[D] (900.00)
<1>
0.000...300.000 RPM
p214hysterresis 2[D] (2.00)
n_hysteresis 1
n_thresh val 2
0.00...210 000.00 RPM
p2155[D] (900.00)
1
1
0
0
<1>
0.00...300.00 RPM
p2140[D] (90.00)
n_hysteresis 2
3
4
n_thresh val 3
0.00...210 000.00 RPM
p2161[D] (5.00)
1
0
t_on cmpr val rchd
0.0...10 000.0 ms
<1>
p2156[D] (0.0)
0.00...300.00 RPM
p2150[D] (2.00)
n_hysterresis 3
T
0
n_thresh val 2
t_on cmpr val rchd
0.0...10 000.0 ms
Monit config
p2156[D] (0.0)
p2149
1
1
0
0
1
<1>
0.00...300.00 RPM
p2140[D] (90.00)
0
n_hysteresis 2
1
5
6
fp_8010_54_eng.vsd
20.04.10 V04.05.00
p0115[3] (4000.00 μs)
p0115[3] (<3>)
ZSW Monitor 3
r2199
r2199.0
[2537.3]
|n_act| < p2161
ZSW Monitor 3
r2199
r2199.1
[2537.3]
f or n-comparison value
reached/exceeded
ZSW Monitor 1
T
0
r2197
r2197,1
[2534.3]
t_on cmpr val rchd
|n_act|
p2155
0.0...10 000.0 ms
p2156[D] (0.0)
ZSW Monitor 1
T
0
r2197
1
r2197.2
[2534.3]
|n_act| > speed threshold value 2
0
7
8
Function diagram