Signal sources for CU_ZSW1
Signal
Meaning
CU_ZSW1.0
Reserved
CU_ZSW1.1
Reserved
CU_ZSW1.2
Reserved
CU_ZSW1.3
1 = Fault present
CU_ZSW1.4
Reserved
CU_ZSW1.5
Reserved
CU_ZSW1.6
Reserved
CU_ZSW1.7
1 = Alarm present
CU_ZSW1.8
1 = System time synchronized (SYNC)
CU_ZSW1.9
1 = No alarm present
CU_ZSW1.10
1 = No fault present
CU_ZSW1.11
1 = No safety message present
CU_ZSW1.12
Slave sign-of-life bit 0
CU_ZSW1.13
Slave sign-of-life bit 1
CU_ZSW1.14
Slave sign-of-life bit 2
CU_ZSW1.15
Slave sign-of-life bit 3
<1> Used in telegrams 390 to 394.
1
2
DO: CU_G, CU_S
PROFIdrive - CU_ZSW1 status word 1 Control Unit interconnection
Interconnection
parameters
p2081[3] = r2139.3
p2081[7] = r2139.7
p2081[8] = r0899.8
p2081[9] = r3114.9
p2081[10] = r3114.10
p2081[11] = r3114.11
Implicitly
interconnected
<2> The ZSW1 is generated using the binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...p2088[0].15)
3
4
[Function diagram]
[Function diagram]
Internal status word
signal source
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
6
Function diagram
fp_2496_54_eng.vsd