Samsung SINAMICS G130 Mode D'emploi page 1103

Table des Matières

Publicité

Signal targets for E_DIGITAL_1
Signal
Meaning
E_DIGITAL_1.0
Reserved
E_DIGITAL_1.1
Reserved
E_DIGITAL_1.2
Reserved
E_DIGITAL_1.3
Reserved
E_DIGITAL_1.4
Reserved
E_DIGITAL_1.5
Reserved
E_DIGITAL_1.6
Reserved
E_DIGITAL_1.7
Reserved
E_DIGITAL_1.8
Digital input 16 (DI 16)
E_DIGITAL_1.9
Digital input 17 (DI 17)
E_DIGITAL_1.10
Digital input 18 (DI 18)
E_DIGITAL_1.11
Digital input 19 (DI 19)
E_DIGITAL_1.12
Digital input 20 (DI 20)
E_DIGITAL_1.13
Digital input 21 (DI 21)
E_DIGITAL_1.14
Digital input 22 (DI 22)
E_DIGITAL_1.15
Reserved
<1> Used in telegrams 393 to 396.
1
2
DO: CU_G, CU_S
PROFIdrive - E_DIGITAL_1 interconnection
<2>
<2>
<2>
<2> Not for CU320-2.
<3> Pre-assignment, can be freely changed.
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
<3>
Internal status word
signal target
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
p2083[8] = r0722.16
-
p2083[9] = r0722.17
-
p2083[10] = r0722.18
-
p2083[11] = r0722.19
-
p2083[12] = r0722.20
-
p2083[13] = r0722.21
-
p2083[14] = r0722.22
-
-
-
5
6
fp_2500_54_eng.vsd
21.09.11 V04.05.00
PROFIdrive sampling time
<1>
Refer to [1020.7]
Inverted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
8
Function diagram
- 2500 -