Maintenance instructions:
Attention!
Prior to any maintenance work, the device must be isolated from power and compressed air.
Lift and secure the Rotor (13) by hand.
Remove the control unit (9) completely together with the location plate.
Loosen the screws and remove guide cassette(11).
Check the guide bolt (11.2) in respect of any damage or wear and exchange, if necessary.
Grease the cam shaft (8) complete with a brush.
Install the guide (11) in reverse to the above.
Clean the change-over station (17-19) and all proximity switches and associated stop screws. Check all
connections and pneumatic hoses.
35