Prepare
and clean
lock pocket
Connecting cables
Prepare the lock
Fasten the lock
Fasten the appropriate
striking plate
Fasten the locking
cylinder with the
cylinder fixing screw
Check for complete
functionality
EN
64
Preparation for mounting
1
Create the lock pocket at a suitable mounting position in the door leaf. Factor in an additional 30 mm
for the cable loop for the depth.
2
Drill the holes for the fastening screws according to the figures shown below (depending on the
selected components).
3
Drill the holes for the lock fittings.
4
Clean the lock pocket and all holes by blowing them out or vacuuming.
Electrical connections
1
Prepare the wiring for the electric multi-point lock 819N
("Electrical connection", page 68).
2
Connect the cables for the power supply and control unit.
Installing the electric multi-point lock 819N
1
Adjust the closing direction of the control latch ("Adjusting the closing direction of the latch", page 66).
2
Adjust the panic side ("Changing the panic side", page 67).
3
Fasten the electric multi-point lock 819N fully in the lock pocket with M5x45 EN 965 screws.
4
Fasten the lock fittings.
5
Check the electric multi-point lock 819N for ease of movement.
 Once the striking plate has been mounted, the electric multi-point lock 819N is ready for use.
Mounting the striking plate
1
Finish the striking plate pocket and all holes or finish a customer-provided striking plate ("Production
of customer-provided striking plates", page 74).
2
Clean the striking plate pocket and all holes by blowing them out or vacuuming.
3
Screw in the appropriate striking plate for the electric multi-point lock 819N to be screwed in complete-
ly with M5x45 EN 965 screws.
4
Check the electric multi-point lock 819N for ease of movement.
 The electric multi-point lock 819N is ready for operation.
Installing fittings and locking cylinders
1
Install the fittings.
2
Insert the locking cylinder and ensure that the locking cylinder nose is in the centre position (Fig. 18).
3
Fix the locking cylinder into place with the fixing screw.
 The electric multi-point lock 819N is completely installed.
Testing the electric multi-point lock 819N
1
Test all functions of the electric multi-point lock 819N.
2
Check whether the latch and auxiliary latch bolt of the lock are pushed back by the same impact edge.
3
Check whether all bolts can freely extend and retract without transverse shear stress after installation
(Fig. 7).
 The electric multi-point lock 819N is completely installed and has been tested for functionality.