Electrical connection

Installing and connecting the cable
The connecting cable must be guided in the door leaf from the lock side to the hinge side. Then the cable
must be routed from the door leaf into the door frame.
1
Observe the following when routing the connecting cable:
· We recommend routing the cable within the door leaf in a suitable conduit having a minimum
diameter of 7 mm.
· Do not kink the conduit and make any necessary bends as wide as possible.
· In order to avoid damaging the cable, it may only be guided around rounded corners.
· A flexible lead cover must be mounted for the transition from door leaf to frame, whereby the cover
is firmly connected to the door leaf and frame (chapter "Electric multi-point lock 819N", page 44).
2
Connect the cable to the electric multi-point lock 819N as specified in the connection diagram and
according to the connection diagrams of the control system.
3
Ensure that the mains adapter matches the electric multi-point lock 819N ("Technical data", page 77).
Factor in the voltage loss over the connecting cable to ensure that the lock functions safely.