4.4.1

Power supply and external enable signal

The Connexx control unit is supplied via a built-in 24 VAC, 15 W transformer. The
transformer primary side is connected to a 230V 50/60Hz mains voltage.
The Connexx system may be released or blocked with an external enable signal through a
primary unit (jumper, terminal 20/21).
The product removal process is released as soon as the lateral master switch is set to "ON"
and the external enable signal is present (optional).
The enable signal for the dosing pumps (pump enable) is only delivered, if the required level
in the lifting vessel has been reached and the external enable signal is present (optional).
Fig. 4.9
Connexx Basic (182603)
417101375_Connexx.doc
Fig. 4.10
Connexx Switch (182604)
- 41 -