6.4

EMP II E60 diaphragm metering pump

Fig. 8: Suction lance connection (pos. I) and water meter pulse input (pos. II)
6.4.1

Hydraulic installation

General information:

Fig. 9: Examples of installation of the EMP II E60
n
In order to minimise the degassing of the product, we recommend that you keep the
metering and suction lines as short as possible!
n
Long and labyrinthine suction lines can lead to accumulation of air in the system.
n
The suction height may not exceed 2 m!
(see
linktarget [417101964 12 Technische Daten] doesn't exist but @y.link.required='true'
n
The suction line must always be installed sloping upwards towards the metering pump.
)