Decommissioning, dismantling, disposal
DANGER!
Danger of injury from pressurised components!
With improper handling, pressurised components can move uncontrollably
and cause severe injuries.
Liquid under high pressure can escape from pressurised components if
handled improperly or in the case of a defect. This can lead to severe or
fatal injuries.
– Establish a pressure-free state.
– Discharge any residual energy.
– Make sure that liquids cannot discharge accidentally.
– Immediately call in qualified staff to replace defective components
which are pressurised during operation.
DANGER!
Chemical hazards (metering medium/active substance)
Risk of injury to the skin and eyes caused by the chemical used
(metering medium).
– Read the enclosed safety data sheet carefully before using the metering
medium.
– The safety regulations and the required protective clothing when
working with chemicals must be complied with.
– Attention must be paid to the information included on the product data
sheet for the metering medium used.
ENVIRONMENT!
Leaked, spilled metering media may be harmful to the environment.
Leaked, spilled metering media must be cleaned and disposed of correctly,
according to the instructions on the safety data sheet.
It is essential to ensure that the required personal protective equipment is
used.
13.2

Shutting down

DANGER!
The procedures described here may only be carried out by skilled
personnel using PPE.
The procedure for shutting down is as follows:
1.
Before carrying out any subsequent work, isolate the electrical supply completely
first of all and secure it against being switched on again.
2.
Physically disconnect the entire power supply; dissipate stored residual energy.
3.
Drain and remove operating fluids and consumables.
4.
Remove the remaining processing materials and dispose of them
in an environmentally-friendly way.