Honeywell IAQPoint2 Guide De Démarrage Rapide page 46

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IAQPoint2™
Configure\Configure Passwords & Reset\Reboot
This will force the monitor to reboot�
NOTE
!
There is no confirmation screen after pressing the [Reboot]
button�
Calibrate menu
Calibrate
Calibrate Gas
Cal Temperature
Calibrate RH
Calibration procedures are initiated at the Calibrate menu� Refer to local regulations
for calibration requirements� Calibrate the monitor at least once a year to maintain
the highest level of accuracy�
Calibrate\Calibrate Gas
Calibrate Gas
Mode:
normal
Conc.
676
ppm.
Target
0 ppm
This screen is visible only on models with the CO
password has been entered� Calibration cannot be performed if Automatic Baseline
is enabled, as it is by default (see Configure\Configure Outputs\Automatic Baseline
above)�
The top line shows the current state of the gas sensor� Possible values include:
• normal
• in base cal
• base cal pass
• base cal fail
• in fault
40
sensor and only after the level-2
2

Publicité

Chapitres

Table des Matières
loading

Table des Matières