Description Of Device / Spare Parts; Possible Faults - ATIKA T 205 Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26

Description of device / spare parts

Nr. Denomination
1
Longitudinal stop
2
Guide bar
3
Mitre stop
4
Table extension
5
Table top
6
Crossfeed stop
7
Thumb screw
8
Splitting wedge
9
Saw blade
10
Protective cover
11
Table insert
12
Locking screw for tilt position
13
On / Off Switch
14
Hand wheel for height adjustment
15
Pushstick
16
Thumb screw
17
Table support brace

Possible faults

Before each fault clearance
− Switch off device
− wait for stop of saw
− Pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Machine fails to start after
switching on or switches off during
idle running
Machine stops while cutting
Workpiece sticks when feeding
Burned spots at the cut areas
Chip outlet is clogged
Saw vibrates
All manuals and user guides at all-guides.com
Order number
363250
363251
363252
363253
363254
362718
363255
363256
363257
363258
363259
363260
363261
361110
Possible cause
• Power failure
• Extension cable defect
• Motor or switch defect
• Saw blade sticks
• Saw blade blunt
• Feed is too great
• Saw blade is dull
• The longitudinal stop is not parallel to the
saw blade
• Saw blade is not suitable for the work step or
is dull
• No exhaust system connected
• Exhaust power too weak
• Saw blade is warped
• Saw blade not properly mounted
23
Nr. Denomination
18
Base frame
19
Hand wheel for tilt position
20
Wing screw
21
Locking screw for guide bar
22
Chip box lid
23
Screws for chip box lid
24
Ring spanner
25
Flat spanner
26
Extractor connecting piece
27
Screw for protective cover
28
Screw for splitting wedge
29
Screw for crossfeed stop
30
Nut for saw blade
31
Flange, front
32
Screw for table insert
33
Flange, rear
34
Safety label
Removal
• Replace fuse
• Check cable, no longer use defect cable
• Have motor or switch checked by an
approved electrician or replaced by original
spare parts
• Remove the cause of the jam.
• Replace saw blade
• Allow motor to cool and proceed working with
less pressure
• Hold the workpiece firmly and switch the
motor off immediately. The have the saw
blade sharpened or renew
• Readjust the scale, see p. 21
• Replace saw blade or have it sharpened
• Switch off saw, remove chips and connect
exhaust system
• Switch off saw, remove chips and increase
exhaust power (air velocity 20 m/sec at chip
exhaust neck.
• Replace saw blade
• Mount saw blade properly
Order number
363261
363283
363262
363263
363264
363280
363282
390002
391007
363265
363281
363266
363267