Report preview and
report function
(ECG acquisition and
analysis software for
Android Tablet)
B.3 Safety Standard
EN 60601-1:2006
IEC 60601-2-25:2011
IEC 60601-2-51:2003
IEC 60601-1-2
Shell case protection class
Anti-electric-shock type
Anti-electric-shock degree: Type CF with defibrillation-proof
Degree of safety of appli-
cation in the presence of
flammable gas:
Working mode:
B.4 Dimension and Weight
Main Unit Dimension
Package Size
Net weight/ Gross weight
B.5 Power Supply Requirements
1) USB power supply: Calibration Voltage=5V
2) Input Power: 2x1.5V Excell Alkaline AAA Calibration Voltage= 3V
B.6 Environment Conditions
Transportation
Storage
Operation
Fonctionnement
a. Report format: the 12 lead model has 14 report formats: horizontal 12x1, horizontal
6x2 + 1R, horizontal 3x4 + 1R (one row), horizontal 3x4 + 1R (three rows), horizontal
3x4 + 3R, horizontal 1R (three rows), horizontal 1R (six rows), vertical 12x1, vertical
6x2 + 1R, vertical 3x4 + 1R (one row), vertical 3x4 + 1R (three rows), vertical 3x4 + 3R,
vertical 1R (six rows);
ECG report output format: ECG grid, colorful report, ECG dot and high QRS wave-
form gain are automatically halved;
b. rhythm lead report mode is supported
c. AGC is supported
d. automatic preview report after data acquisition is supported
e. network printer is supported
f. automatic print preview after data acquisition is supported
Medical electrical equipment - Part1: General requirements for basic safety and essen-
tial performance
Medical electrical equipment - Part 2-25: Particular requirements for the basic safety
and essential performance of electrocardiographs
Medical electrical equipment - Part 2-51: Particular requirements for safety, including
essential performance, of recording and analysing single channel and multichannel
electrocardiographs
Medical electrical equipment - Part 1-2: General requirements for basic safety and
essential performance - Collateral Standard: Electromagnetic disturbances - Require-
ments and tests
IPX0, without waterproof function
Special power supply equipment, internal power supply equipment; (when it is
connected to the power supply network, the equipment providing power to it shall
meet the requirements of class I or class II equipment)
Equipment not suitable for use in the presence of flammable gas
Continuous operation
68 mm×126 mm×24 mm
70 mm×330 mm×85 mm
0.85 kg /1.7 kg
Temperature
-20 °C to +55 °C
-20 °C to +55 °C
+5 °C to +40 °C
www.spengler.fr
Relative humidity
≤ 93%
≤ 93%
≤80%, sans condensation
118
Atmospheric pressure
50kPa~106kPa
50kPa~106kPa
86kPa~106kPa