Technical Specifications - Nice Ten TN2010 Instructions Et Recommandations Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66

8) Technical specifications

For purposes of product improvements, Nice S.p.a. reserves the right to apply modifications to technical specifications at any time when
deemed necessary, while maintaining the same functionalities and intended use.
All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C).
Technical specifications: TEN
Model
Type
Maximum start-up torque
Nominal torque
Speed under no-load
Speed at nominal torque
Maximum operating cycle frequency at nominal
torque (the control unit restricts the maximum
number of cycles as specified in tables 3 and 4) *
Maximum continuous operating time at nominal
torque (the control unit restricts the maximum
number of cycles as specified in tables 3 and 4) **
Limits of use
Durability
TEN Power supply
TEN/V1 Power supply
Maximum power absorbed on start-up
[corresponding to Amperes]
Insulation class
Emergency Power supply
Courtesy light
Flashing light Output
BlueBUS Output
STOP input
SS input
Open input
CLOSE input
Radio AERIAL input
Radio connection
Programmable functions
Functions in self-learning mode
Operating temperature
Use in particularly acid, saline or potentially
explosive environments
Protection rating
Dimensions
Weight
*
At 50°C the maximum operating frequency is (cycles/hour)
** At 50°C the maximum continuous operating time is (minutes)
30
TN2020
/
320 Nm
220Nm
1.4 (24Vcc)
0.9 (24Vcc)
25 cycles per hour
14 minutes
In general TEN is able to automate balanced doors with surface areas up to 8m
up to 14 m
2
with 2 motors, within the limits specified in table 2.
Estimated at between 10000 and 50000 cycles, according to the conditions specified in table 5
24 Vcc (-30% +50%)
130W (5.5A)
III
/
/
/
/
/
/
/
/
/
/
/
IP 44
512 x 150 h 158
7.2 Kg
TN2010
TN2010
Electromechanical gearmotor for the automatic movement of
projecting and non-projecting up-and-over doors for residential
use, complete with electronic control unit
350 Nm
240 Nm
1.7rpm; the control unit enables programming of 6 speeds
1.2rpm
15 cycles per hour
22 minutes
230Vac (-10% +15%) 50/60Hz.
120Vac (-10% +15%) 50/60Hz.
240W (1A)
[2A version V1]
I
Yes
12V/10W fitting BA15S
For 1 flashing light model
LUCYB;MLB or MLBT (lamp
12V, 21W)
An output with maximum load
of 12 BlueBUS units
For normally closed and nor-
mally open contacts or with
constant
resistance
of
8,2Kohm; in self-learning mode
(a status variation generates
the "STOP" command)
For normally open contacts
(closure of the contact genera-
tes the SS command)
For normally open contacts
(closure of the contact gener-
ates the OPEN command)
For normally open contacts
(closure of the contact gener-
ates the CLOSE command)
52 ohm for cable type RG58 or
similar
SM connector for receiver
types SMXI, SMXIS or OXI
8 ON-OFF type functions and 8
adjustable functions (see tables
8 and 10)
Self-learning of devices connect-
ed to BlueBUS output.
Self-learning of "STOP" type
devices (contacts NO, NC or
8,2K resistance) Learning of
door opening and closing posi-
tions and calculation of the
points of deceleration and partial
opening.
-20°C ÷ +50°C
No
10 Kg
TN2020
4
6
12
6
TN2010+TN2020
500 Nm
330 Nm
25 cycles per hour
14 minutes
2
with 1 motor and
350W (1.4A)
[3A version V1]
I
/
/
/
/
/
/
/
/
/
/
TN2010+TN2020
4
7

Publicité