7.7.2) Signals on control unit

The TEN control unit is equipped with a series of LEDs, each of
which provide specific signals, both during normal operation and in
the event of faults (Figure 31).
Table 21: Leds on control unit terminals
BLUEBUS led
Off
On
One flash per second
2 quick flashes
Series of flashes separated by
a pause of one second
STOP led
Off
On
SS led
Off
On
OPEN led
Off
On
Led CLOSE
Off
On
Table 22: leds on control unit keys
Led L1
Off
On
Flashing
Led L2
Off
On
Flashing
Led L3
Off
On
Flashing
Cause
Malfunction
Serious Malfunction
All Ok
An input status has varied
Various
Cause
Stop input activation
All Ok
Cause
All Ok
SS input activation
Cause
All Ok
OPEN input activation
Causa
All Ok
CLOSE input activation
Description
During normal operation, indicates "Automatic closure" not active.
During normal operation, indicates "Automatic closure" active.
• Function programming in progress
• If this flashes together with L2 this indicates that the device learning phase must be performed (see
paragraph "4.2 Learning devices").
Description
During normal operation, indicates "Re-close after photo" not active.
During normal operation, indicates "Re-close after photo" active.
• Function programming in progress
• If this flashes together with L1 this indicates that the device learning phase must be performed (see para-
graph "4.2 Learning devices").
Description
During normal operation, indicates "Always close" not active.
During normal operation, indicates "Always close" active.
• Function programming in progress
• If flashing together with L4, indicates that the door opening and closing acquisition procedure must be per-
formed (see paragraph "4.3 – Learning the door opening and closing positions").
31
ACTION
Check for presence of the power supply; check that the fuses are not blown;
in this case, identify the cause of the fault and then replace with versions with
the same specifications.
This indicates a serious fault; try switching off the control unit for a few sec-
onds; if the condition persists there is a fault and the electronic board needs
to be replaced
Normal operation of control unit
A variation to the status of the inputs SS, STOP, OPEN, CLOSE, activation of
the photocells, or when the radio transmitter is used, is normal.
This is the same signal as on the flashing light See table 20
ACTION
Check the devices connected to the STOP input
STOP input active
ACTION
SS input not active
Normal if the device connected to the SS input is effectively active.
ACTION
OPEN input not active
Normal if the device connected to the OPEN input is effectively active.
AZIONE
CLOSE input not active
Normal if the device connected to the CLOSE input is effectively active.