7.3.5) Learning other devices
Normally the operation for learning devices connected to BlueBUS
and the STOP input is performed during the installation phase; how-
ever if other devices are added or removed, the learning procedure
can be repeated as described below.
1. Press and hold keys [▲] and [Set] (Figure 28)
2. Release the keys when leds L1 and L2 start to flash quickly (after
around 3s)
3. Wait a few seconds for the control unit to finish device self-learn-
ing.
4. At the end of the self-learning process, the STOP led must
remain lit, while leds L1 and L2 turn off (where relevant leds L3
and L4 start flashing).
After adding or removing devices, the automation test
cycle must be repeated as described in paragraph "5.1
Testing".
7.3.6) Deleting the entire memory
When total deletion is required, to restore factory settings, proceed as follows with the motor stationary.
1. Press [▲] + [▼] for 3 seconds; release the keys when all leds illuminate simultaneously.
Leds L1 and L2 start flashing at the end of the procedure.
!
This procedure does not modify the parameter for the direction of Ten rotation or the encoder position.

7.3.7) Programming the direction of motor rotation

Ten is factory set to execute the opening manoeuvre as shown in figure 5. The direction of rotation can be inverted by programming the open-
ing manoeuvre as shown in figure 7.
Procedure for programming the direction of motor rotation
1.
Press and hold [Set] for approx. 3s
2
Release [Set] when led L1 starts flashing
3.
Press keys [▲] and [▼] at the same time to modify the motor direction
4.
Release keys [▲] and [▼]
• If the courtesy light is lit, the inverted direction of motor rotation has been programmed
• If the courtesy light is off, the standard direction of motor rotation has been programmed
5.
Wait 10s to exit programming mode in timeout.
Note: Points 3 and 4 can be repeated during the same programming phase to change the direction of motor rotation.
When the direction of motor rotation is changed, the "Position memorisation" procedure must be repeated.
Checking the programmed direction of motor rotation
To check the set direction of motor rotation, proceed as follows:
1.
Disconnect Ten from the power supply (removing the plug or fuse)
2.
Power up Ten
3.
After the initial flash of leds L1 to L8 a single led illuminates to indicate the encoder position.
4.
On the signal indicating the encoder position, check the courtesy light:
• If the courtesy light is lit, the inverted direction of motor rotation has been programmed
• If the courtesy light is off, the standard direction of motor rotation has been programmed