3.5.1) Description of electrical connections

This paragraph provides a brief description of the electrical connections: for further information refer also to "7.3 Adding or removing devices"
FLASH
this output is programmable (see L4 in table 10) to connect one of the following devices:
Flashing light
If programmed as "flashing light" the "FLASH" output can be connected to a NICE "LUCY B" MLB or MLBT flashing light
with a 12V 21W car type lamp.
During the manoeuvre the light flashes at an interval 0.5s on and 0.5s off
Function: "door open indicator", "active if door closed" or "active if door open"
If programmed with one of these 3 functions, the "FLASH" output can be connected to a 24V max 5W indicator light to
signal the following:
"Door open indicator" function
Off: door closed
Slow flashing: Door opening
Quick flashing: Door closing
On: Door open (not closed)
"Active if door closed" function
On: door closed
Off: All other cases
"Active if door open" function
On: Door open
Off: All other cases
It may also be programmed for other functions; in the case refer to paragraph "7.2.3 Level 2 functions (adjustable para-
meters)"
Suction cup*
If programmed as "suction cup" the "FLASH" output can be connected to a 24V max 10W suction cup (versions with
electromagnet only, without electronic devices).
When the door is closed, the suction cup is activated to lock the door in place. During the opening and closing manoeu-
vre it is deactivated
Electric block*
If programmed as "electric block" the "FLASH" output can be connected to a max. 24V electric lock with latch (versions
with electromagnet only, without electronic devices).
During the opening manoeuvre, the electric lock is activated and remains active to free the door and perform the
manoeuvre. In the closing manoeuvre ensure that the electric block re-engages mechanically.
Electric lock*
If programmed as "electric lock" the "FLASH" output can be connected to a 24V max 10W electric lock with latch (ver-
sions with electromagnet only, without electronic devices).
During the opening manoeuvre, the electric lock is activated for a brief interval to free the door and perform the manoeu-
vre. In the closing manoeuvre ensure that the electric block re-engages mechanically.
BLUEBUS
this terminal enables the connection of compatible devices; all are connected in parallel with just two wires conveying
the electric power and communication signals. More information on BlueBUS is available in paragraph "7.3.1 - BlueBUS".
STOP
Input for devices that block or shut down the manoeuvre in progress; by setting the input accordingly, it is possible to
connect Normally Closed type contacts, Normally Open contacts, constant resistance or optical devices. More informa-
tion on STOP is available in paragraph "7.3.2 –STOP input".
PP
Input for devices that control movement in Step-Step mode, enabling the connection of Normally Open contacts.
OPEN
Input for devices that control opening movement only, enabling the connection of Normally Open contacts.
CLOSE
Input for devices that control closing movement only, enabling the connection of Normally Open contacts.
AERIAL
Input for connection of the aerial for the radio receiver (the aerial is incorporated on LUCY B)
* Only devices containing exclusively the electromagnet can be connected
!
Never use devices other than those specified