UK | 9 Mounting
If connecting more than two units, we recom-
mend wiring in a double flush-mounted box or
in an additional flush-mounted box.
9.7 Mounting
RLS 45 O
1. Take off room air control's front panel.
2. Set up unit pairs.
Unit pair
Ventilation unit
Fan 1* exhaust
1
2
3
* In the cross-ventilation operating mode,
this ventilation unit switches to exhaust air.
** In case of an uneven number of ventilation
units, the smaller number of devices is
connected to the fan 1 terminals.
3. Connect ventilation unit cables of the
same Fan1 or Fan2 group to the plug-in
connection terminal  Wiring diagrams in
the appendix. If necessary, use a separate
distribution box.
Recommendation: If there are more
i
than 2 ventilation units, install the room
air control in a switch box to be sup-
plied by the customer. This provides
sufficient space for the connection of
the cables to the room air control.
Additional ventilation units can be used
i
when using PP 45 LT power units.
4. Insert room air control in the recessed-
mounted box and screw down to re-
cessed-mounted box with 2 screws.
40
and
RLS 45 K
Ventilation unit
Fan 2
air
Unit 1.1
Unit 1.2
Unit 2.1
Unit 2.2
Unit 3.1
Unit 3.2
5. Fit front panel. Ensure that the sensor
opening lies above the integrated
PP 45 HYI (if present).
6. Start up ventilation system  Chapter 10.

9.8 Mounting radio switch (EnOcean)

When radio mode is activated, En-
i
Ocean radio components, such as
master or slave units or sensors, can
be taught-in directly on ventilation
units. For range of radio components
 Technical data.
Purely radio-
Combi system
controlled
system
DS 45 RC
+
PP 45 RC
PP 45 RC
PPB 30 RC
...
PPB 30 O/K
Purely radio-controlled PP 45 system
1. Simply glue
DS 45 RC
location on the wall. Alternatively, the radio
switch can also be screwed onto the wall
(mounting material provided by customer).
2. Use the "Learn button" to activate teaching-
in mode on the ventilation unit. For more
information about teaching-in Operating
instructions, Chapter 7.
3. For basic unit settings, such as "Block Off
function"  Installation instructions.
PP 45 combi system with
PP 45 EO extension module can only
i
be combined with PP 45 RC unit pairs.
Wired operation is needed for other
unit types.
RLS 45 K
PP 45 EO
+
+
max. 6
PP 45 RC
PP 45 K
PPB 30 RC
PP 45 O
or
max. 3
to installation
PP 45 EO