6 Requirements of the installation
site
● Ambient temperature - 15 °C to + 40 °C.
● Airstream temperature max. 40 °C.
● Max. permissible humidity in installation
room 70 % (at 20 °C).
● A level and solid wall surface is needed for
wall installations.
● For filter changes, ensure sufficient space to
work in front of the unit.
● Do not drill core drill hole for unit assembly
and do not drill fixing points on external and
internal covers in load-bearing components,
such as in the lintel or ring beam
6 Requirements of the installation site | UK

7 Technical data

External diameter
Wall sleeve max. length 500 or 800 mm
Wall thickness min.
max.
Air filter outside
Air filter inside
Air volume/unit
Protection class
Degree of protection
Sound pressure level,
distance 1 m, free-field
conditions (ventilation
level 1 to 5)
Rated voltage/
power frequency
Volumetric flows for
ventilation level
1, 2, 3, 4, 5
Power consumption
Weight
slide-in module cpl.
Permissible ducting
lengths
with wired
connection
Radio components:
Frequency range (in acc.
with EN 300220-1)
"Wireless" operating
distances in the building
are dependant on the
building materials used:
DS 45 RC  PP 45 RC
PP 45 EO  PP 45 RC
PP 45 RC  PP 45 RC
● With PP 45 RC as
signal booster
Ø 160
265 mm
490 or 790 mm
G3
G2
42 m³/h
II
IP 00
23 / 28 / 33 /
37 / 40 dB(A)
230 V
50/60 Hz
15 / 20 / 30 /
36 / 42 m³/h
1.2 / 1.7 / 2.1 /
2.8 / 3.5 W
3 kg
From star point
max. 25 m per
ventilation unit
868.35 MHz
up to:
30 m
30 m
30 m
40 m
33