Installing Humidity Sensor Pp 45 Hyi - Maico PP 45 O Notice De Montage

Masquer les pouces Voir aussi pour PP 45 O:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Install EnOcean extension module
For more information  Accessories in-
structions. If necessary, include a separate
distribution box in the wiring planning.
2. Connect EnOcean extension module to
control (RS485)  Wiring
RLS 45 K
diagrams in the appendix.
3. Start up ventilation system, activate in
EnOcean service mode  Chap. 10.
EnOcean-Actor PP 45 Act
The PP 45 Act can be used to combine
radio-controlled PP 45 RC devices with wired
exhaust air units (ECA, ER). Installation simi-
lar to light switch installation; can be switched
on and off at the touch of a button. For more
information  Accessories instructions.
9.9 Installing humidity sensor
In wired systems, the integrated humidity sen-
sor is inserted into the
room air control. In
units, the integrated humidity sensor is in-
stalled directly in the ventilation unit.
For installation and wiring of an external sen-
sor  Installation instructions.
Installing humidity sensor in
RLS 45 K
1. Install room air control as described before.
NOTICE
Unit damage/no function if the humidity
sensor is installed incorrectly. Do not bend
pins. Insert sensor up to stop in bush.
2. Insert humidity sensor
interface  Arrow.
PP 45 EO
PP 45 HYI
RLS 45 O
RLS 45 K
or
PP 45 RC
radio-controlled
RLS 45 O
PP 45 HYI
at I2C
Fit front panel. Make sure it locks into
i
position. Front panel has NO pro-
tection against twisting. Ensure that
sensor opening (hole in front panel) is
above the sensor.
3. Start up ventilation system and register
humidity sensor in service mode
 Chap. 10.
Installing humidity sensor
lation unit
Only insert the integrated humidity
i
sensor in the master ventilation unit.
1. Take off front cover of internal cover's
housing. To do this, press on locking lever
on underside of housing and take off cov-
er.
2. Loosen screw for board cover, take off
board cover.
or
NOTICE
No function if the humidity sensor is in-
stalled incorrectly. Do not bend pins. Insert
sensor up to stop in bush.
3. Insert humidity sensor
4. Fit board cover.
5. Attach front cover of internal housing at
top in two housing studs and swivel down
until front cover engages on locking lever.
6. Start up ventilation system and register
humidity sensor in service mode  Chap-
ter 10.4.
9 Mounting | UK
in radio venti-
PP 45 RC
PP 45 HYI
 Arrow.
41