Mounting instructions

ER-RPK replacement kit
(article no. 0093.1563)
Scope of delivery
- 1x blind plug
- 1x retaining bolt
- 1x central retaining bolt for cover
- 1x exhaust adapter
- 1x housing floor seal
- 1x adapter board
- these instructions
Intended use
The ER-RPK replacement kit is used for
mounting the ER EC fan insert in ER-UP/G,
ER-UPD, and ER-UPB housing.
Safety instructions and
warnings
WARNING
Risk of injury when working at heights.
Use appropriate, certified climbing aids
Stability should be ensured, if
(ladders).
necessary have the ladders steadied by a
2nd person.
Ensure that you are standing securely
and cannot lose your balance and that there
is no one under the unit.
CAUTION
Intended operation not ensured if
installed incorrectly. A fan not installed
correctly may result in operation not as
intended.
Only install fan in accordance with the
planning documents.
In particular, note the models on
ventilation channels and sound deadening.
DANGER
Danger from operating with the fan not
fully mounted. Electric components are
a potential source of electric shock.
If the unit is open, all off the supply
circuits must be switched off (mains fuse
off), secured against being accidentally
switched back on and a visible warning sign
positioned.
 Only operate the fan when it is
completely installed.
 Do not cover the fan.
DANGER
Danger if the relevant regulations for
electrical installations are not
observed.
Before removing the upper housing
part/fan insert and before installing the
electrics, switch off all supply circuits as well
as the mains fuse and secure them against
being accidentally switched back on again.
Attach a warning sign in a clearly visible
place.
 Be sure to observe the relevant
regulations for electrical installation; e.g.
DIN EN 50110-1, in Germany this is
particularly VDE 0100, with the
corresponding parts.
 A mains isolation device with contact
openings of at least 3 mm at each pole is
mandatory.
 Only connect unit to permanently wired
electrical installation and with NYM-O or
NYM-J cables, depending on the unit
variant, 3x 1.5 mm² or 5x 1.5 mm².
The units may only be operated using the
voltage and frequency shown on the rating
plate.
5