OPERATION

LOWERING THE LIFT.

The control handle MUST be in the OPEN position (con-
trol valve positioned away from pump handle) to lower
O
the boom and the patient. The rate of descent can be
P
controlled by varying the amount that the control valve
E
is opened.
R
NOTE: A safety gate is part of the hydraulic
A
system that controls the maximum descent of the
T
boom regardless of how far the control valve is opened.
I
1. WITH the patient in a sling, gently open the control
O
valve.
N
2. WITHOUT the patient in a sling, open the control
valve and pull DOWN on the boom.
Pump Handle
Closed
Control Valve
Open
Pump Handle
Closed
Control Valve
Open
FIGURE 3 - LOWERING THE MANUAL /
HYDRAULIC PATIENT LIFT
Raising/Lowering Electric Lift (FIGURE 4)
Invacare does NOT recommend locking of the
rear casters of the patient lift when lifting an indi-
vidual. Doing so could cause the lift to tip and en-
danger the patient and assistants. Invacare DOES
recommend that the rear casters be left UNLOCKED
during lifting procedures to allow the patient lift to
stabilize itself when the patient is initially lifted from
a chair, bed or any stationary object.
OPERATION (CONT.)
With Patient
Without Patient
WARNING

RAISING THE LIFT.

Press the UP (é) button to raise the boom and the
patient lift.
LOWERING THE LIFT.
Press the DOWN ( ) button to lower the boom and
ê
the patient.
Press EMERGENCY DOWN BUTTON on Control Box.
Pull UP on EMERGENCY RING and push DOWN on the
boom at the same time.
MECHANICAL "EMERGENCY" RELEASE
All lift actuators are equipped with a mechanical "Emer-
gency" release. The mechanical release will enable
the actuator to retract without power. The actuator will
only retract while under load and the mechanical
"Emergency" release is pulled.
The release is colored reddish orange with the word
"Emergency" spelled out in white. To activate the re-
lease, one must grab the ring collar and pull upward.

EMERGENCY STOP.

Press the RED button on the control box IN to stop the
lift arms and patient from raising or lowering.
UP Button
Hand Control
DOWN
Button
Control
Box
Press IN to
Stop Boom
FIGURE 4 - RAISING/LOWERING THE
ELECTRIC PATIENT LIFT
10
Rotate CLOCKWISE
to Disengage
Emergency Stop
Push DOWN on Boom.
Pull UP
on EMERGENCY
Ring.

Publicité