PROPANE GAS UNIT
SYMPTOM
Burner will not light or stay alight
Irregular flame pattern. Flame does
not run the full diameter of burner
Flame is yellow or orange
44
CAUSE
No gas flow
Obstruction of gas flow
Faulty Hose Valve Regulator
Burner is off the valve
Spider webs or obstruction in burner
tube
Burner ports blocked
Faulty Burner
Bad igniter spark
Burner ports blocked
Burner may be blocked
Spider webs or obstruction in burner
tube
Food residue or grease on burner
Burner is off the valve
Fuel/Air mixture incorrect
Burner may have residue
SOLUTION
Confirm LP Gas cylinder is full and valve is turned to
"open".
Check for bent or kinked regulator
Clean burner ports.
Call for replacement.
Re-engage burner onto the valve.
Clean burner tube. Use a soft wire brush to clear
plugged ports
Clean burner ports.
Call for replacement.
Check to see if electrode is producing spark. The spark
should be visible and jumping from the igniter to the
burner. If you cannot see any spark you may need to
slightly adjust the position by bending the electrode
a little closer or further away from the burner. Replace
igniter or replace the igniter wire. Call Dansons for
replacement.
Check to make sure your battery in your igniter is good.
Refer to owners manual for replacement. Check to see
if burner will match light.
Clean burner ports. Use a soft wire brush to clear
plugged ports
Clean burner ports.
Clean burner tube.
Clean burner.
Re-engage burner onto the valve.
You may need to adjust the primary air shutter to allow
more air into the burner
Turn burner to high setting for 5 min and burn with the
door open.