Télécharger Imprimer la page

Abus TERXON M Instructions D'installation page 186

Publicité

Les langues disponibles

Les langues disponibles

Technical data
Voltage supply
External voltage supply:
UK
External power consumption:
Internal voltage supply:
Internal power supply:
CPU power consumption:
Power consumption of control unit:
Emergency power supply:
Outputs
Transistor outputs:
Loudspeaker:
AUX:
Relay outputs:
Additional Transistor outputs:
Inputs
TR:
Telephone fault:
Fuses
F1 – 12V AUX:
F2 – battery:
Specifications
Dimensions:
Weight:
Internal time:
Environment:
230V AC +/-10% (ambient temperature 20°C)
1.0A maximum
19VAC / -10%
2.0A maximum
150mA maximum
35mA maximum
12V DC, 7.0Ah lead rechargeable battery
12V DC, 0.5A maximum, negative switching
2 x 16 Ohm loudspeakers parallel,
12V DC / 0.5A maximum
24V DC / 1A maximum
12VDC, 0.05A max.
Tamper input from siren
+12V DC if fault present
230V, 1A quick-acting
230V, 2A quick-acting
390mm x 310mm x 95mm (HxWxD)
5kg
+/- 10 min./year, synchronised to mains frequency
-10°C to +55°C max. 96% humidity
90

Publicité