Abus TERXON M Instructions D'installation page 153

Publicité

Les langues disponibles

Les langues disponibles

5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
IMPORTANT: Changing the length of the access code
requires that all codes be reset to the factory settings. From
the factory: 4 numbers (1234 for user, 7890 for installer); 6
numbers (123456 for user, 567890 for installer).
057 Battery test
To change the property of the battery test:
1. On the control unit, enter:
2. The LCD display shows: 057: BattTest OFF
3. Via the keypad, select from the following items and
press:
BattTest OFF
0
No battery test is carried out.
BattTest ON
A battery test is carried out if deactivated
or 23 hours after the last test (neg.:
1
display „battery fault" in the control unit +
short tone)
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
058 BVVO Sabotage reset
Proceed as follows to change the property of the BVVO
sabotage reset:
1. On the control unit, enter:
2. The LCD display shows: 058: BVVOtamp OFF
3. Via the keypad, select from the following items and
press:
BVVOtamp OFF
The user can carry out a reset in case of
0
tampering when the alarm centre is
deactivated.
BVVOtamp OFF
1
057
.
058
57
If the alarm centre is deactivated in case
of tampering then an installer reset is
required.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
059 Sabotage siren
Proceed as follows to change the property of the sabotage
siren:
1. On the control unit, enter:
2. The LCD display shows: 059: BellTamp=NEG
3. Via the keypad, select from the following items and
press:
BellTamp=NEG
There is no resistor in the sabotage loop
0
(NC)
BellTamp=EOL
The sabotage loop is protected by a
1
2.2kOhm resistor (EOL)
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
060 Entry/exit behaviour on internal active (B)
To change the zone property of the entry/exit zone at internal
active (B):
1. On the control unit, enter:
2. The LCD display shows: 060: B=FE =FE
3. Via the keypad, select from the following items and
press:
B=FE =FE
A zone programmed as entry/exit keeps
this property even for internal activation
0
and thus starts the entry delay time when
the zone triggers and during active
.
059
.
060
UK