105 Test call
To change the properties of the test call:
4. On the control unit, enter:
5. The LCD display shows: 105:Day Hour=00
UK
6. Via the keypad, select from the following items and
press:
00
A nn
B nn
C nn
D nn
6. Confirm your input. On the control unit, enter:
7. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
106 Line loss report
To change the settings of the line loss report:
7. On the control unit, enter:
8. The LCD display shows: 106:LF=Audible
9. Via the keypad, select from the following items and
press:
0
1
105
OFF
Day Hour
Daily test call to the alarm centre at the
required time 01-24.
Month Day
Monthly test call to the alarm centre on
the required day 01-28.
Freq Hour
The alarm centre makes a test call
every nn hours (e.g. every 12 hours).
Freq Days
The alarm centre makes a test call
every nn days.
106
OFF
LF=Audible
When deactivated, the alarm centre writes
the loss in the event memory and emits a
short tone every minute at the control unit.
The tone is silenced on entering the
access code and the control unit shows a
line loss on the display. The system can
still be activated, despite the loss.
When activated, the alarm centre writes
the loss in the event memory but no tone
is emitted from the control unit and
nothing is displayed. If there is an alarm
during a line loss then all siren delays are
switched off.
LF=Silent
When deactivated, the alarm centre writes
the loss in the event memory and shows
the loss in the display of the control unit.
When activated, the alarm centre writes
2
the loss in the event memory but shows
nothing on the display. If there is an alarm
during a line loss then all siren delays are
switched off.
8. Confirm your input. On the control unit, enter:
9. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
108 Dynamic test call
.
To change the properties of the dynamic test call:
1. On the control unit, enter:
2. The LCD display shows: 108:Dynamic OFF
3. Via the keypad, select from the following items and
press:
Dynamic OFF
0
Dynamic test call is switched off.
Dynamic ON
The alarm centre carries out a test call 24
1
hours after the last communication.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
70
.
108
.