4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
061 Entry to follow behaviour on internal
active (B)
To change the zone property for internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 061: B=ER =ER
3. Via the keypad, select from the following items and
press:
0
1
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
internal activation.
B=FE = NA
A zone programmed as entry/exit changes
its zone property during internal activation
to immediate and triggers an alarm if the
zone triggers and during active internal
activation.
061
B=ER =ER
A zone programmed as entry to follow
keeps this property even during internal
activation and permits entry to this zone
during the entry delay period.
B=ER = FE
A zone programmed as entry to follow
changes its zone property during internal
activation to entry/exit and starts the delay
time if the zone triggers and during active
internal activation.
062 Behaviour of exist mode internal active (B)
To change the property of the exit mode for internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 062: B=LEISE
3. Via the keypad, select from the following items and
press:
.
Low Tone
The acoustic signal during the exit delay
0
time is emitted at half volume.
Instant
During internal activation, the alarm
1
centre is internally activated immediately –
i.e., without delay.
Silent
No acoustic signal is emitted during the
2
delay time. Following expiry of the delay
time, the alarm centre emits a brief signal.
B=A
The initial mode for internal active B is as
3
for the initial mode of overall active A
In a partitioned system
B=Timed
Activation of partition B after exit time
(command 65). A connected key switch at
0
the control unit shortens the exit time when
activated
B=Terminated
Activated via key switch connected to the
1
control unit. The exit time is unlimited.
B=Final Door
Activation of the partition by closing the
2
.
last door detector
B=Instant
3
Active without delay time
B=Silent
Use command 65 for the exit time. The
4
control unit emits a double beep when the
time has expired.
B=Lock Set
5
Key switch (see command 39)
58