Télécharger Imprimer la page

Abus TERXON M Instructions D'installation page 170

Publicité

Les langues disponibles

Les langues disponibles

4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
UK
126 Change language
To change the language used for the control unit display:
10. On the control unit, enter:
11. The LCD display shows: 126:Lang=English
12. Via the keypad, select from the following items and
press:
00
01
02
03
04
05
06
07
08
09
10. Confirm your input. On the control unit, enter:
11. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
128 External alarm
All radio transmitters are monitored via the radio expansion
unit. If a radio zone has not communicated with the radio
expansion unit for more than 2 hours then this reports a
monitoring error. The external alarm function describes how
the alarm centre reacts to this fault. To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 128:Full Alarm
3. Via the keypad, select from the following items and
press:
126
ENGLISH
ITALIAN
ESPANOL
PORT
NEDERL
FRANCAI
GERMAN
NORW.
SWED.
DANSK
128
.
Full Alarm
0
Sirens + call to central station
Local Alarm
1
Internal, external + control unit tone
Keypads only
2
Comms only
3
Inhibit Set
Control unit tone; the alarm centre can
4
not be activated until the faulty detector
reacts
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
129 Deactivate external
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 129:ExtUnset OFF
3. Via the keypad, select from the following items and
press:
ExtUnset OFF
The user must first enter the entry zone
.
and thereby start the entry time before he
0
is able to deactivate using the remote
control.
ExtUnset OFF
The user can deactivate the alarm centre
1
without entering the entry zone.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
131 SIA report mode
To change the settings:
1. On the control unit, enter:
2. The LCD display shows: 131:Mode=Basic
74
.
129
.
131

Publicité

loading