4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
023 Remote reset
This function allows a remote reset via the COM interface or
the PC connection. IMPORTANT: System reset by installer
must be activated (function 33 to 1) and CSID (function 50)
must be set.
1. On the control unit, enter:
2. The LCD display shows: 023:RemReset OFF
3. Via the keypad, select from the following items and
press:
0
1
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
After the alarm, the user can switch off the alarm using the
access code, although he can not reset the alarm centre. The
user contacts the central station which identifies him and
transmits a signal back to the alarm centre. The user can now
carry out a reset.
024 Account name
This function shows you the account name. From the program
level, do the following:
ChimeVol
Specify the volume of the internal alarm
issued via the control unit and the
(optional) loudspeaker.
Press:
off
0
quiet
1
loud
9
023
RemReset OFF
Fern Reset AUS
RemReset ON
Fern Reset AN
1. On the control unit, enter:
2. Via
you leave the menu.
3. The control unit shows Installer Mode.
025 Internal alarm
To change the property of the internal alarm:
4. On the control unit, enter:
.
5. The LCD display shows: 025:LS Timed
6. Via the keypad, select from the following items and
press:
LS Timed
The internal alarm follows the entered
0
times for the external siren
LS Cont
The internal alarm sounds until the alarm
1
centre is deactivated.
6. Confirm your input. On the control unit, enter:
7. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
027 Alarm on failed activation
To change the property of the alarm on failed activation,
proceed as follows:
1. On the control unit, enter:
.
2. The LCD display shows: 027:Internal
3. Via the keypad, select from the following items and
press:
Internal
If activation fails, the alarm is issued via
0
the internal signaller.
Local
If activation fails, the alarm is also issued
1
via the external siren.
4. Confirm your input. On the control unit, enter:
48
024
025
.
027
.