Abus TERXON M Instructions D'installation page 161

Publicité

Les langues disponibles

Les langues disponibles

Chime OFF
Pressing the Forbikobler door bell does
0
not activate the loudspeaker of the alarm
centre.
Chime ON
Pressing the Forbikobler door bell
1
activates the loudspeaker of the alarm
centre.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
081 Relay output OP1
To change the behaviour of relay output OP1 on the
alarm centre PCB:
1. On the control unit, enter:
2. The LCD display shows: 081: Bell
3. Via the keypad, select from the following items and
press:
Bell
This output is activated at local and
00
external alarms. Set the siren delay and
duration in menu items 41 and 42.
EE Follow
This output is activated if the entry/exit
delay is active. Note that this output is not
01
activated if the exit mode "internal" is
programmed to "silent" or "immediate".
Armed Lamp
This output is activated if the alarm centre
02
is completely or internally activated.
Set Latch
This output is activated if the alarm centre
is completely or internally activated. The
03
output is also activated if the alarm centre
is reset or if a walk test is started.
Shock sensor reset
This output is activated for 5 seconds at
04
the start of the exit delay.
.
081
65
Walk Test
This output is activated during the user
and programmer walk test. The output is
05
connected to the walk test input of the
motion sensor.
Ready Lamp
This output is activated if the alarm centre
is ready for complete or internal
06
activation. The alarm centre is ready even
if the zones with the properties "entry/exit"
or "entry to follow" are opened.
24 Hour
This output is activated if a 24-hour zone
triggers an alarm. The output is
07
deactivated if the alarm centre is
deactivated.
Strobe
This output is activated if a local or
external alarm is triggered. The output
08
remains active until the alarm centre is
deactivated.
Smoke Reset
This output is used to reset smoke
detectors. This output is activated for at
09
least 3 seconds following every
deactivation and reset of the alarm centre
following an alarm.
Siren Test
This output is activated following
10
programming and during a siren test
(command 91 in the program menu).
Strobe Set
This output is activated for 10 seconds
after the alarm centre is activated and the
11
alarm centre is active. The output can be
used to issue an active acknowledgement.
Set 1
This output is activated for a definable
time period (command 170) if the alarm
12
centre is activated completely (A) or
internally (B), (C) or (D) (command 171).
UK