Télécharger Imprimer la page

Abus TERXON M Instructions D'installation page 159

Publicité

Les langues disponibles

Les langues disponibles

075 Exit delay time internal C
To change the property of the exit delay time for internal
active C:
1. On the control unit, enter:
2. The LCD display shows: 075: E C=10
3. Via the keypad, select from the following items and
press:
Exit C=10
Exit delay time for internal active C is 10
1
seconds.
Exit C=20
Exit delay time for internal active C is 20
2
seconds.
Exit C=30
Exit delay time for internal active C is 30
3
seconds.
Exit C=45
Exit delay time for internal active C is 45
4
seconds.
Exit C=60
Exit delay time for internal active C is 60
5
seconds.
Exit C=120
Exit delay time for internal active C is 120
6
seconds.
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer mode.
076 Behaviour of exit mode internal (D)
To change the property of the exit mode for internal active
(D):
1. On the control unit, enter:
2. The LCD display shows: 076: D=Low Tone
3. Via the keypad, select from the following items and
press:
075
.
076
63
D=Low Tone
The acoustic signal during the exit delay
0
time is emitted at half volume.
D=Instant
During internal activation, the alarm
1
centre is internally activated immediately –
i.e., without delay.
D=Silent
No acoustic signal is emitted during the
2
delay time. Following expiry of the delay
time, the alarm centre emits a brief signal.
D=A
The initial mode for internal active B is as
3
for the initial mode of overall active A
In a partitioned system
D=Timed
Activation of partition D after exit time
(command 79). A connected key switch at
0
the control unit shortens the exit time when
activated
D=Terminated
Activated via key switch connected to the
1
control unit. The exit time is unlimited.
D=Final Door
Activation of the partition by closing the
2
last door detector
D=Instant
3
Active without delay time
D=Silent
Use command 79 for the exit time. The
4
control unit emits a double beep when the
time has expired.
D=Lock Set
5
Key switch (see command 39)
4. Confirm your input. On the control unit, enter:
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
UK
.

Publicité